Pipework (NB) Jacket Size ØOD ØID ØRF ØP.C.D NH ØH T Length Lining Thk.
Inches mm mm mm mm mm mm mm mm mm mm mm
1" 25 50 152.4 19 60 120.6 4 19.0 19.0 200 - 3000 3.5
1.1/2" 40 65 177.8 34 80 139.7 4 16.0 22.2 200 - 3000 3.5
2" 50 80 190.5 45 100 152.4 4 19.0 23.8 200 - 3000 3.5
2.1/2" 65 100 228.6 55 113 190.5 8 19.0 23.8 200 - 3000 3.5
3" 80 100 228.6 69 135 190.5 8 19.0 23.8 200 - 3000 4.0
4" 100 150 279.4 92 165 241.3 8 22.2 25.4 200 - 3000 4.0
6" 150 200 342.9 144 225 298.4 8 22.2 28.6 200 - 3000 4.5
8" 200 250 406.4 192 280 361.9 12 25.4 30.2 300 - 3000 5.0
10" 250 300 482.6 241 325 331.8 12 25.4 31.8 300 - 3000 5.5
12" 300 350 533.4 296 391 476.2 12 28.6 34.9 300 - 3000 6.0
Item Des. Material
Lining PTFE, PP, HDPE, PVDF, Antistatic
Pipe ASTM A 106 Gr. B, SS 304, SS 316, SS 316L
Flange IS 2062, SA 105N, SS 304, SS 316, SS 316L
Pipe Schedule Sch. 10, Sch. 20, Sch. 30, Sch. 40, Sch. 60, Sch. 80,
Sch. 100, Sch. 120, Sch. 140, Sch. 160
Flange Rating ASME B 16.5 - Cls. 150, Cls. 300, Cls. 600
BS 10 - Table D, Table E, Table F, Table H, Table J & Table K
DIN Standard - PN 6, PN 10, PN 16, PN 25 & PN 40

Testing Specification

  • 100% Visual Check / Dimensional Check
  • 100% Hydro Test at 29.9 kg/cm2(g) for holding time of
    3 Mins. as per ASTM F 1545 - 15A
  • 100% Spark Test at 10 kv after Lining
  • 100% Lining Thk. to be checked.
    (>80% of Flaring Thk.)